Industry Application

LNG & Natural Gas Processing

Cryogenic and gas processing valves for LNG liquefaction, boil-off gas handling, storage and regasification.

LNG & Natural Gas Processing

LNG & Natural Gas Processing

Industrial Valves for LNG and Natural Gas Processing

Natural gas processing involves the removal of impurities, separation of hydrocarbons and preparation of gas for transportation or liquefaction. During LNG production, treated natural gas is cooled to approximately −162°C (−260°F), reducing its volume for storage and transportation.

Valves installed in these facilities operate under conditions ranging from high-pressure gas service to extremely low-temperature liquid handling. Thermal contraction, material toughness, seat leakage and stem sealing are particularly important in cryogenic applications.

As an LNG and natural gas valves supplier in USA, ValvesOnly provides cryogenic ball, gate, globe and check valves alongside control valves and automated isolation configurations for gas treatment, liquefaction, storage and regasification systems.

Valve Applications in LNG and Natural Gas Processing

Natural Gas Treatment and Purification

Before liquefaction, natural gas undergoes treatment to remove carbon dioxide, hydrogen sulfide, moisture, mercury and other impurities that could interfere with downstream operations.

Ball and gate valves provide equipment isolation in gas treatment units, while globe and control valves regulate gas flow and treatment fluids. Material selection depends on gas composition, operating pressure and exposure to corrosive contaminants.

Natural Gas Liquefaction

Liquefaction units use refrigeration cycles to progressively reduce the temperature of treated natural gas. Valves are installed in refrigerant circuits, cold box connections, heat exchanger systems and LNG transfer lines.

Cryogenic ball, globe and gate valves are selected for low-temperature fluid isolation and regulation. Extended bonnet construction, suitable low-temperature materials and controlled sealing clearances help accommodate thermal contraction.

LNG Storage and Loading Systems

LNG storage tanks and loading facilities require valves for liquid withdrawal, tank isolation, transfer lines and vapor return systems.

Cryogenic trunnion ball valves and automated emergency isolation valves may be specified for these applications. Valve selection must account for shutoff performance, trapped liquid expansion, actuator requirements and emergency shutdown conditions.

Boil-Off Gas Management

Heat entering LNG storage and transfer systems causes a portion of the liquid to vaporize, generating boil-off gas. This gas may be recovered, compressed, reliquefied or directed to fuel gas systems.

Control valves regulate gas flow and pressure, while check valves prevent reverse flow in compressor discharge and gas recovery circuits. Operating temperature and pressure may vary considerably across these systems.

LNG Regasification

Regasification terminals convert stored LNG back into gaseous form through vaporization. Valves are installed in LNG pump discharge lines, vaporizer connections and natural gas send-out systems.

Cryogenic isolation valves are required on the liquid side, while conventional high-pressure ball, gate and control valves may be used downstream of the vaporizers where operating temperatures permit.

Emergency Shutdown and Isolation Systems

Emergency shutdown systems isolate selected sections of LNG facilities during abnormal operating conditions. Automated cryogenic ball valves and emergency cut-off valves may be integrated with these systems.

Valve closure time, actuator sizing, fail-safe position and shutoff performance must be established according to the facility's safety requirements and hydraulic conditions.

Common Types of Valves Used in LNG and Natural Gas Processing

Cryogenic Ball Valves

Cryogenic ball valves provide quarter-turn isolation in LNG transfer lines, liquefaction units and storage systems. Extended stem or bonnet configurations help maintain stem packing at a temperature suitable for sealing. Cavity pressure relief arrangements must be evaluated where liquid can become trapped inside the valve body.

Cryogenic Gate Valves

Cryogenic gate valves provide full-opening isolation in low-temperature piping systems. Extended bonnet construction and suitable body and trim materials accommodate cryogenic operating conditions while minimizing heat transfer toward the stem sealing assembly.

Cryogenic Globe Valves

Cryogenic globe valves are used for isolation and selected flow regulation applications in LNG and refrigeration circuits. Long stem and extended bonnet designs help separate the packing assembly from the low-temperature fluid.

Cryogenic Check Valves

Cryogenic check valves restrict reverse flow in LNG pump discharge lines, liquid transfer systems and low-temperature fluid circuits. Disc construction, installation orientation and closure characteristics are important considerations.

Trunnion Ball Valves

Trunnion ball valves are used in high-pressure natural gas handling and larger pipeline isolation applications. Cryogenic configurations may also be specified for LNG transfer systems where the valve construction and materials are qualified for the operating temperature.

Control Valves

Control valves regulate gas flow, refrigerant circulation, pressure and liquid levels within natural gas treatment and liquefaction units. Cryogenic control applications require suitable bonnet construction, trim materials and flow characteristics.

Emergency Cut-Off Valves

Emergency cut-off valves provide automated isolation of designated LNG and natural gas circuits. Actuator selection, fail-safe operation and closure performance depend on the facility's emergency shutdown philosophy.

Technical Specifications

Valve requirements vary between natural gas treatment, cryogenic liquid handling and regasification systems.

Parameter Typical Specifications
Valve Types Cryogenic Ball, Gate, Globe, Check, Control and Emergency Cut-Off
Nominal Sizes NPS ½ to 48, depending on valve design
Pressure Ratings ASME Class 150, 300, 600, 900, 1500 and 2500, where applicable
Operating Temperature Cryogenic configurations for temperatures down to −196°C (−321°F), where qualified
Body Materials Austenitic Stainless Steel, Low-Temperature Carbon Steel, Nickel-Based Alloys
Representative Material Grades ASTM A351 CF8/CF8M/CF3M, A182 F304/F316/F316L, A352 LCB/LCC, A350 LF2
End Connections Flanged, Butt Weld, Socket Weld, Threaded
Operation Manual, Gear, Pneumatic, Electric
Bonnet Construction Extended Bonnet, Long Stem, Bolted Bonnet
Seat Construction Cryogenic-Compatible Soft Seats, Metal Seats
Safety Features Cavity Pressure Relief, Anti-Static Construction, Fail-Safe Actuation, where applicable

Low-temperature carbon steel grades are intended for suitable noncryogenic or moderately low-temperature gas applications within their qualified limits. They are not generally suitable for direct LNG service at −162°C.

Design Standards and Inspection Requirements

Standard Application
BS 6364 Valves for cryogenic service
ISO 28921-1 Design, manufacturing and production testing of low-temperature isolation valves
ISO 28921-2 Type testing of low-temperature isolation valves
ASME B16.34 Valve design and pressure-temperature ratings
API 6D Applicable pipeline and piping valve designs
API 608 Metal ball valves
API 600 Steel gate valves
API 602 Compact steel gate, globe and check valves
API 598 Valve inspection and pressure testing
API 607 / API 6FA Fire testing for applicable valve designs
ISO 15848-1 Fugitive emissions testing and qualification
IEC 60534 Industrial process control valves
ANSI/FCI 70-2 Control valve seat leakage classification

Cryogenic valve inspection may include low-temperature seat leakage testing, external leakage testing, operational torque measurements and material verification. Testing temperature, acceptance criteria and qualification requirements depend on the applicable standard and project specifications.

Material Selection for LNG and Natural Gas Valves

Materials used in LNG systems must retain suitable mechanical properties at extremely low temperatures. Austenitic stainless steels are commonly considered for cryogenic valve construction because of their low-temperature toughness.

Material Representative Grades Application Considerations
Austenitic Stainless Steel 304 ASTM A351 CF8, A182 F304 Selected LNG and cryogenic fluid handling applications
Austenitic Stainless Steel 316 ASTM A351 CF8M, A182 F316 Cryogenic applications requiring suitable corrosion resistance
Low-Carbon Stainless Steel 316L ASTM A351 CF3M, A182 F316L Selected welded cryogenic valve configurations
Low-Temperature Carbon Steel ASTM A352 LCB/LCC, A350 LF2 Natural gas and moderately low-temperature applications within qualified limits
Carbon Steel ASTM A216 WCB, A105 Noncryogenic natural gas processing and distribution
Nickel-Based Alloys Selected Inconel and other nickel alloy grades Specialized trim, sealing and corrosion requirements

Material suitability must be established for the complete valve assembly, including the body, bonnet, stem, trim, seats, packing and bolting.

Key Factors When Selecting LNG and Natural Gas Processing Valves

  • Minimum design temperature: Confirm that valve materials and sealing components are qualified for the lowest anticipated operating temperature.
  • Thermal contraction: Evaluate dimensional changes between the body, stem, seats and internal components during cooling.
  • Extended bonnet construction: Ensure that the stem packing remains within its permissible temperature range.
  • Cavity pressure relief: Address pressure buildup caused by the thermal expansion of trapped cryogenic liquids.
  • Cryogenic leakage performance: Establish acceptable internal and external leakage limits under low-temperature conditions.
  • Installation orientation: Follow the specified bonnet orientation, insulation clearance and flow direction requirements.
  • Emergency isolation: Confirm actuator sizing, fail-safe position and closure time for automated shutdown applications.
  • Gas composition: Evaluate moisture, hydrogen sulfide, carbon dioxide and other contaminants when selecting valves for upstream gas treatment.
  • Inspection and testing: Specify cryogenic testing, pressure testing and material documentation according to project requirements.

ValvesOnly supplies industrial valve configurations for natural gas treatment, LNG liquefaction, storage terminals and regasification facilities across the USA. For technical inquiries, provide the fluid composition, minimum design temperature, operating pressure, valve size, material grade, end connection and cryogenic testing requirements.

Recommended Valves for LNG & Natural Gas Processing

17 Linked Products
Cryogenic Gate Valve

Cryogenic Gate Valve

Cryogenic Gate Valve from Valves Only.

View
Double Block and Bleed Ball Valve

Double Block and Bleed Ball Valve

Double Block and Bleed Ball Valve from Valves Only.

View
Forged Trunnion Ball Valve

Forged Trunnion Ball Valve

Forged Trunnion Ball Valve from Valves Only.

View
Cryogenic Steam Jacket Globe Valve

Cryogenic Steam Jacket Globe Valve

Cryogenic Steam Jacket Globe Valve from Valves Only.

View
Cryogenic Short Stem Globe Valve

Cryogenic Short Stem Globe Valve

Cryogenic Short Stem Globe Valve from Valves Only.

View
Pneumatic Trunnion Forged Ball Valve

Pneumatic Trunnion Forged Ball Valve

Pneumatic Trunnion Forged Ball Valve from Valves Only.

View
Fully Welded Ball Valve

Fully Welded Ball Valve

Fully Welded Ball Valve from Valves Only.

View
Top Entry Ball Valve

Top Entry Ball Valve

Top Entry Ball Valve from Valves Only.

View
Casting Trunnion Ball Valve

Casting Trunnion Ball Valve

Casting Trunnion Ball Valve from Valves Only.

View
Cryogenic Check Valve

Cryogenic Check Valve

Cryogenic Check Valve from Valves Only.

View
Cryogenic Emergency Cut off Valve

Cryogenic Emergency Cut off Valve

Cryogenic Emergency Cut off Valve from Valves Only.

View
Forged Cryogenic Trunnion Ball Valve

Forged Cryogenic Trunnion Ball Valve

Forged Cryogenic Trunnion Ball Valve from Valves Only.

View

Need the right valve for your process?

Talk to our application engineers for a tailored recommendation and a fast quote.